<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>gc</ParameterFamily>
<LongName>
away_plate_rotate
</LongName>
<Name>
aprot
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter rotates the image on the plate to compensate for the position of
the plate registration pins. This parameter is calibrated during factory
integration and normally should not change after this.  Adjustments should be
made with advice from factory integrators.
</text></DescriptionText>
<DescriptionText><text>
A positive rotation angle will rotate the image in a counter-clockwise
direction.
</text></DescriptionText>
<DescriptionText><text>
This parameter specifies the rotation for the away-side broadsheet plate.  This
is the plate on the left when looking at the Trendsetter from the front.
</text></DescriptionText>
<DescriptionText><text>
Only plates smaller than 450mm will use these two pins.
</text></DescriptionText>
</Description>
<Type>
integer
</Type>
<Default>
<UnnumberedList>
<li>-1000</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>-32767 to 32767 [microrads]</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
When loading the plate onto the drum, the plate is not aligned in the center.  The plate
is positioned so that its center line is 221mm to the left of the device center line.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/gc_cal_prot.xml</LinkAddress><LinkTitle>NVS: gc prot</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:48 2008 PST
</Updated>
<Links>
</Links>
</Parameter>